Dimensions are minimums; any combination of UL1 & UL2 longer than listed is acceptable. For more information or to discuss meter run lengths, please contact CPA!

CPA 50E/55E/65E Ultrasonic Flow Meter Installations, Gas or Liquid

  • Canada Pipeline Accessories’ minimum general recommended meter run length is 10 internal pipe diameters when using the CPA 50E, 55E and 65E in ultrasonic applications.
  • For UL1, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe as measured from the upstream face (inlet) of the flow conditioner.
  • For UL2, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe from the downstream face (outlet) of the flow conditioner to the upstream flange of the ultrasonic meter.

CPA TBR/50E/55E AGA3‐2000/ISO‐5167 Custody Transfer Orifice Installations, Gas or Liquid

  • For all AGA3‐2000/ISO‐5167 custody transfer orifice measurement applications, CPA recommends a minimum meter run length of 13D or 17D for the CPA TBR/50E and 13D for the CPA 55E.
  • For 13D installations, a minimum UL1 upstream length of 5 internal diameters and a minimum UL2 downstream length of 8 internal diameters is required.
  • For 17D installations, any combination of UL1 and UL2 is acceptable as long as UL2 is a minimum of 8 internal pipe diameters, and the total overall meter run length is at least 17 internal diameters.
  • UL1 is measured from the last disturbance to the upstream face of the flow conditioner.
  • UL2 is measured from the outlet of the flow conditioner to the upstream face of the orifice plate.
  • This is independent of fluid type and is recommended for all gas or liquid applications.

CPA 65E Gas/Liquid Flow Meter General Installations

  • Canada Pipeline Accessories’ minimum recommended meter run length is 10 internal pipe diameters.
  • This is applicable to all flow meters (turbine, ultrasonic, vortex, annubar, venturi) as these distances were determined independently of any specific meter type.
  • For UL1, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe as measured from the upstream face (inlet) of the flow conditioner.
  • For UL2, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe from the downstream face (outlet) of the flow conditioner to the flow meter in question.
  • For turbine, ultrasonic or any other flanged meters, UL2 is measured to the flange connection at the flow meter inlet.
  • For venturi meters, UL2 is measured to venturi inlet or upstream tap (a venturi calibration is recommended to maximize performance of the flow meter).
  • The 65E is not recommended for AGA3 orifice applications!

CPA 55E Gas/Liquid Flow Meter General Installations

  • Canada Pipeline Accessories’ minimum recommended meter run length is 10 internal pipe diameters.
  • This is applicable to all flow meters (turbine, vortex, annubar, venturi, non‐custody transfer orifice) as these distances were determined independently of any specific meter type.
  • For UL1, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe as measured from the upstream face (inlet) of the flow conditioner.
  • For UL2, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe from the downstream face (outlet) of the flow conditioner to the flow meter in question.
  • For orifice meters, UL2 is measured to the upstream face of the orifice plate.
  • For turbine, ultrasonic or any other flanged meters, UL2 is measured to the flange connection at the flow meter inlet.
  • For venturi meters, UL2 is measured to venturi inlet or upstream tap (a venturi calibration is recommended to maximize performance of the flow meter).

CPA 50E Gas/Liquid Flow Meter General Installation

  • Canada Pipeline Accessories’ minimum recommended meter run length is 10 internal pipe diameters.
  • This is applicable to all flow meters (turbine, vortex, annubar, venturi, non‐custody transfer orifice) as these distances were determined independently of any specific meter type.
  • For UL1, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe as measured from the upstream face (inlet) of the flow conditioner.
  • For UL2, CPA recommends a minimum of 5 internal diameters of uninterrupted straight pipe from the downstream face (outlet) of the flow conditioner to the flow meter in question.
  • For orifice meters, UL2 is measured to the upstream face of the orifice plate.
  • For turbine, ultrasonic or any other flanged meters, UL2 is measured to the flange connection at the flow meter inlet.
  • For venturi meters, UL2 is measured to venturi inlet or upstream tap (a venturi calibration is recommended to maximize performance of the flow meter).